    OPTO SWITCHER
    This free-standing unit allows the remote switching of mains powered equipment such as illuminated signs, cue lights etc., while maintaining electrical isolation from the mains. Control on type 42-682 is implemented using either a closing contact across XLR pins 1 & 3, or by applying 5-15 volts DC across XLR pins 2 & 3. Switching occurs at the zero-crossing point of the mains cycle, which, together with spike suppression components, ensures that interference is virtually eliminated. Mains input and output connectors are IEC (CEE22) 3 pole with a 20mm fuse on the input line. The control input uses an XLR 3 pin female panel connector.

    Mating connector stock codes:

    IEC mains input 42-154
    IEC mains output 42-153
    XLR control input 40-322
    Technical Specification:
    Mains input: 230V AC
    Fuse: 20mm, 6.3A (T) HRC (stock code 42-275)
    Mains output: 1.5kW
    Contact closure output: 5V DC at 17mA (close to switch load on)
    DC input: 5-15V DC (pin 2 positive) (high to switch load on)
    5V DC at 9mA
    15V DC at 40mA
    The control voltage may be increased up to 50V DC by adding a 1k resistor in series with the positive input.

    Control to mains isolation: 1.5kV
    Dimensions: 107mm ×93mm ×50mm